Specification:
HW156
Tray Cable – Control Cable
600 Volt UL Type TC, 90°C
FR-XLP VW-1 XHHW-2 Insulation
Copper Conductors
| Catalog Number | Size AWG | No. of Conductors | No. of Strands | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inch | Net Weight Lbs/Mft |
|---|---|---|---|---|---|---|---|
| HW156 01402* | 14 | 2 | 7 | 30 | 45 | .23 x .37 | 71 |
| HW156 01403 | 14 | 3 | 7 | 30 | 45 | 0.39 | 85 |
| HW156 01404 | 14 | 4 | 7 | 30 | 45 | 0.42 | 105 |
| HW156 01405 | 14 | 5 | 7 | 30 | 45 | 0.46 | 125 |
| HW156 01407 | 14 | 7 | 7 | 30 | 45 | 0.50 | 173 |
| HW156 01409 | 14 | 9 | 7 | 30 | 60 | 0.62 | 241 |
| HW156 01412 | 14 | 12 | 7 | 30 | 60 | 0.68 | 302 |
| HW156 01419 | 14 | 19 | 7 | 30 | 80 | 0.81 | 448 |
| HW156 01425 | 14 | 25 | 7 | 30 | 80 | 0.96 | 631 |
| HW156 01430 | 14 | 30 | 7 | 30 | 80 | 1.04 | 721 |
| HW156 01437 | 14 | 37 | 7 | 30 | 80 | 1.13 | 867 |
| HW156 01202* | 12 | 2 | 7 | 30 | 45 | .25 X .41 | 95 |
| HW156 01203 | 12 | 3 | 7 | 30 | 45 | 0.43 | 135 |
| HW156 01204 | 12 | 4 | 7 | 30 | 45 | 0.47 | 168 |
| HW156 01205 | 12 | 5 | 7 | 30 | 60 | 0.55 | 214 |
| HW156 01207 | 12 | 7 | 7 | 30 | 60 | 0.60 | 290 |
| HW156 01209 | 12 | 9 | 7 | 30 | 60 | 0.69 | 360 |
| HW156 01212 | 12 | 12 | 7 | 30 | 60 | 0.76 | 460 |
| HW156 01219 | 12 | 19 | 7 | 30 | 80 | 0.95 | 663 |
| HW156 01225 | 12 | 25 | 7 | 30 | 80 | 1.08 | 850 |
| HW156 01230 | 12 | 30 | 7 | 30 | 80 | 1.17 | 1003 |
| HW156 01237 | 12 | 37 | 7 | 30 | 80 | 1.27 | 1211 |
| HW156 01002* | 10 | 2 | 7 | 30 | 45 | .27 x .46 | 131 |
| HW156 01003 | 10 | 3 | 7 | 30 | 45 | 0.48 | 169 |
| HW156 01004 | 10 | 4 | 7 | 30 | 60 | 0.56 | 231 |
| HW156 01005 | 10 | 5 | 7 | 30 | 60 | 0.61 | 276 |
| HW156 01007 | 10 | 7 | 7 | 30 | 60 | 0.67 | 328 |
| HW156 01009 | 10 | 9 | 7 | 30 | 60 | 0.78 | 465 |
| HW156 01012 | 10 | 12 | 7 | 30 | 80 | 0.90 | 629 |
| HW156 01019 | 10 | 19 | 7 | 30 | 80 | 1.07 | 900 |
* Flat Construction
Application:
Superior flame-retardant cable for use in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.
Insulation:
Flame-retardant cross-linked polyethylene (FR-XLP) per ICEA S-73-532 and UL Standard 44 for Type XHHW-2, VW-1 conductors.
Jacket:
Sunlight-resistant PVC per UL Standard 1277.
Flame Tests:
•IEEE 383 70,000 BTU/hr flame test
•IEEE 1202 70,000 BTU/hr CSA FT4 flame test
•ICEA 210,000 BTU/hr flame test
•Individual conductors pass the UL VW-1 flame test
Color Code:
ICEA Method 1, Table E-2
Additional Standards:
•UL Type TC per Article 336 of the NEC.
•Approved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.
•NEMA WC 57