Specification:
HW251
Type SEOOW
600 Volt, -50° to 105°C
Yellow Jacket
Flexible Copper Conductors
| Catalog Number | Size AWG | No. of Conductors | No. of Strands | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inch | Net Weight Lbs/Mft |
|---|---|---|---|---|---|---|---|
| HW251 01802 | 18 | 2 | 16 | 31 | 62 | 0.34 | 57 |
| HW251 01803 | 18 | 3 | 16 | 31 | 62 | 0.36 | 69 |
| HW251 01804 | 18 | 4 | 16 | 31 | 62 | 0.39 | 78 |
| HW251 01602 | 16 | 2 | 26 | 31 | 62 | 0.37 | 69 |
| HW251 01603 | 16 | 3 | 26 | 31 | 62 | 0.39 | 80 |
| HW251 01604 | 16 | 4 | 26 | 31 | 62 | 0.42 | 96 |
| HW251 01402 | 14 | 2 | 41 | 47 | 82 | 0.50 | 124 |
| HW251 01403 | 14 | 3 | 41 | 47 | 82 | 0.53 | 149 |
| HW251 01404 | 14 | 4 | 41 | 47 | 82 | 0.57 | 180 |
| HW251 01202 | 12 | 2 | 65 | 46 | 97 | 0.57 | 152 |
| HW251 01203 | 12 | 3 | 65 | 46 | 97 | 0.60 | 197 |
| HW251 01204 | 12 | 4 | 65 | 46 | 97 | 0.64 | 240 |
| HW251 01002 | 10 | 2 | 104 | 46 | 97 | 0.62 | 193 |
| HW251 01003 | 10 | 3 | 104 | 46 | 97 | 0.66 | 257 |
| HW251 01004 | 10 | 4 | 104 | 46 | 97 | 0.70 | 313 |
| HW251 00802 | 8 | 2 | 96 | 48 | 90 | 0.66 | 233 |
| HW251 00803 | 8 | 3 | 96 | 48 | 90 | 0.70 | 327 |
| HW251 00804 | 8 | 4 | 96 | 48 | 100 | 0.78 | 420 |
| HW251 00602 | 6 | 2 | 96 | 48 | 90 | 0.74 | 302 |
| HW251 00603 | 6 | 3 | 96 | 48 | 100 | 0.81 | 458 |
| HW251 00604 | 6 | 4 | 96 | 48 | 100 | 0.88 | 599 |
| HW251 00402 | 4 | 2 | 96 | 48 | 125 | 0.90 | 464 |
| HW251 00403 | 4 | 3 | 96 | 48 | 125 | 0.98 | 667 |
| HW251 00404 | 4 | 4 | 96 | 48 | 125 | 1.09 | 865 |
| HW251 00202 | 2 | 2 | 96 | 50 | 128 | 1.09 | 715 |
| HW251 00203 | 2 | 3 | 119 | 50 | 128 | 1.15 | 971 |
| HW251 00204 | 2 | 4 | 119 | 50 | 128 | 1.26 | 1225 |
Application:
High-grade yellow jacketed cord for use in harsh industrial applications where flexibility and durability is required. Superior insulation and jacketing material allows cable to be used in -50C to 105C environments. Typical uses include stage equipment and lighting, and portable power distribution for tools, equipment, small motors and machinery.
Conductors:
Soft bare annealed copper per ASTM B-3, flexible bunch strand per ASTM B-174.
Insulation:
Thermoplastic elastomer (TPE).
Jacket:
Yellow thermoplastic elastomer (TPE).
Flame Tests:
MSHA flame test
Color Code:
•ICEA Method 1
•Three conductor: black, white, green
Additional Standards:
•NEC Article 400
•Pennsylvania Bureau of Mines MSHA approved
•Federal Specification JC-580B
Note: