5kV/8kV SHIELDED 133% OR 100% – EPR – LS-ZH

Specification:
HW220
Power Cable
5KV/8KV UL Type MV-105-LS, 105°C
Single Conductor, Shielded
EPR Insulation
Low Smoke Zero Halogen Jacket
5KV 133%, 8KV 100% Insulation Level
Copper Conductor

Catalog Number Size AWG/kcmil Number of Strands Insulation Thicknes Insulation Diameter Inch Jacket Thickness Overall Diameter Inch Net weight Lbs/Mft
HW220 00601 6 7 115 0.43 60 0.63 286
HW220 00401 4 7 115 0.50 60 0.71 350
HW220 00201 2 7 115 0.56 60 0.77 460
HW220 00101 1 19 115 0.60 60 0.81 565
HW220 10101 1/0 19 115 0.64 60 0.84 620
HW220 20101 2/0 19 115 0.68 80 0.93 755
HW220 30101 3/0 19 115 0.73 60 0.99 890
HW220 40101 4/0 19 115 0.79 80 1.04 1055
HW220 25001 250 37 115 0.85 80 1.09 1205
HW220 35001 350 37 115 0.95 80 1.20 1570
HW220 50001 500 37 115 1.08 80 1.34 2115
HW220 75001 750 61 115 1.27 80 1.53 2995
HW220 10001 1000 61 115 1.42 80 1.68 3870

Application:
LifeGuard Low Smoke Zero Halogen cable is for use in power circuits in chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. It may be installed in open air, conduit, duct, cable tray when CT rated, or direct buried in earth, in wet and dry locations. It is highly flame retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard cable is ideal for applications where a high degree of safety and equipment protection is required.

It is National Electric Code approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Product Features:
•Cable tray rated on sizes 1/0 AWG and larger
•Sunlight-resistant
•Approved for direct burial
•Very low smoke production when burned
•Highly chemical resistant
•Very flame retardant
•Burns to an ash – does not exhibit thermoplastic drip
•Excellent compression and impact resistance
•Superior tensile strength and abrasion resistance
•Flexible jacket with low coefficient of friction

Conductor:
Compressed soft annealed copper per ASTM B-3, Class B stranding per ASTM B-8, with a semi-conducting conductor shield

Insulation:
Ethylene propylene rubber (EPR) per ICEA S-97-682 Type III with a semi-conducting insulation shield

Shield:
Uncoated copper tape with a 25% overlap per ICEA S-97-682

Jacket:
•Sunlight-resistant and flame-retardant, Low Smoke Zero Halogen polyolefin per UL Standard 1072 and ICEA T-33-655-1994 Section 5-4

Flame Tests:
•IEEE 383 70,000 BTU/hr flame test
•IEEE 1202 70,000 BTU/hr flame test
•UL Standard 1685 70,000 BTU/hr Flame Propagation and Smoke Release Test

Additional Standards:
AEIC C5-8