CONSTRUCTION:
Standed copper conductors, Okoseal insulation with nylon covering on primaries, color coded, twisted into pair or triad, or groups of pairs or triads, numeric print group identification, aluminum/polyester shield and coated stranded copper drain wire over each group with 100% isolation between group shields, multiple groups assembled, aluminum/polyester shield and coated stranded copper drain wire overall, rip cord, Okoseal inner jacket with continuously welded and corrugated C-L-X sheath, with Okoseal jacket.
Pairs: Black/white and numbered color code. Triads: Black/white/red and numbered color code.
SIZES:
#16 AWG
APPLICATION:
For use on Class 1 Remote-Control and Signaling circuits; where a 600V rated cable is desired; for control, signal, and communication circuits; indoors or outdoors, in cable trays, in raceways, direct burial, supported by a messenger in outdoor locations. Suitable for Class I, Division 2 or Class II, Division 2 as well as Class I, Class II, and Class III, Division 1 and Division 2 hazardous locations. Also for use as non power limited fire protective signaling cable (NPLF) per NEC Code 760. Listed by the American Bureau of Shipping (ABS) as CWCMC-MC-HL. IEC certified to 60092-350 (100V). Meets IEEE 1202 vertical tray flame tests. Also passes 210,000 BTU vertical tray flame test per ICEA T-29-520.
SINGLE PAIR & TRIAD CABLES P-OS
| Catalog Number | Conductor Size AWG (strands) | No. of Pairs | No. of Triads | Insulation Thickness-mils | Inner Jacket Thickness mils | C-L-X O.D.-Inches | Outer Jacket Thickness-mils | Approx. O.D.-In. | Approx. Net Wt (lbs/M’) |
|---|---|---|---|---|---|---|---|---|---|
| 564-60-3401 | 16(7X) | 1 | - | 15/4 | 66 | 0.53 | 50 | 0.64 | 182 |
| 564-65-3401 | 16(7X) | - | 1 | 15/4 | 58 | 0.53 | 50 | 0.64 | 190 |
MULTI-PAIR & TRIAD CABLES SP-OS
| Catalog Number | Conductor Size AWG (strands) | No. of Pairs | No. of Triads | Insulation Thickness-mils | Inner Jacket Thickness mils | C-L-X O.D.-Inches | Outer Jacket Thickness-mils | Approx. O.D.-In. | Approx. Net Wt (lbs/M’) |
|---|---|---|---|---|---|---|---|---|---|
| 561-60-3402 | 16(7X) | 2 | - | 15/4 | 50 | 0.67 | 50 | 0.78 | 234 |
| 561-60-3404 | 16(7X) | 4 | - | 15/4 | 50 | 0.80 | 50 | 0.91 | 335 |
| 561-60-3408 | 16(7X) | 8 | - | 15/4 | 50 | 0.93 | 50 | 1.04 | 492 |
| 561-60-3412 | 16(7X) | 12 | - | 15/4 | 50 | 1.11 | 50 | 1.22 | 674 |
| 561-60-3424 | 16(7X) | 24 | - | 15/4 | 50 | 1.42 | 50 | 1.53 | 1118 |
| 561-60-3436 | 16(7X) | 36 | - | 15/4 | 60 | 1.64 | 60 | 1.82 | 1586 |
| 561-65-3404 | 16(7X) | - | 4 | 15/4 | 50 | 0.84 | 50 | 0.95 | 395 |
| 561-65-3408 | 16(7X) | - | 8 | 15/4 | 50 | 1.06 | 50 | 1.17 | 637 |
| 561-65-3412 | 16(7X) | - | 12 | 15/4 | 50 | 1.24 | 50 | 1.35 | 863 |
Alternate C-L-X Cables: